Tuesday, August 30, 2016

RESTRICTIONS FOR SAMPLES RECEPTION

In observance of the National Memorial Day Holiday in USA on Monday, 5th September, we inform you that no samples will be accepted for:


NEOBONA ADVANCE PLUS TEST AND HARMONY

We can not receive samples on 1th, 2th, and 3th September.

The last day to receive samples in our laboratory in Barcelona will be on Wednesday, 31th August until noon.

We will resum our normal hours of samples reception on Monday, 5th September

Monday, August 22, 2016

TRYPTOPHAN, SERUM/PLASMA

Reference values and Method Modification

Test code: 3968

Effective update from 22/08/2016


PREVIOUS
NEW
Childs (µmol/L)       Adults (µmol/L)
     21 - 82                   19 - 73

Method:  
High resolution liquid chromatography
<24 Months
µmol/L
2-17 Years µmol/L
≥18 Years
µmol/L
17-75
23-80
29-77
Method:  
Gas chromatography - flame ionization detector (GC-FID)


   Find the record of the test by clicking here

FENILALANINA / TIROSINA SERUM/PLASMA

Reference values and Method Modification

Test code: 3329

Effective update from 22/08/2016



PREVIOUS
NEW
Phenilalanine    

Childs (µmol/L)     Adults (µmol/L)
     26 - 91           34 - 120

Tyrosine

Childs (µmol/L)   Adults (µmol/L)
       31 -141             31 - 96

Ratio PHENYLALANINE/TYROSINE: less than 3            

Method:  
High resolution liquid chromatography
Phenilalanine
<24 Months
µmol/L
2-17 Years µmol/L
≥18 Years
µmol/L
28-80
30-95
35-80

Tyrosine

<24 Months
µmol/L
2-17 Years µmol/L
≥18 Years
µmol/L
26-115
31-106
31-90

Ratio PHENYLALANINE/TYROSINE: less than 3            

Method:  
Gas chromatography - flame ionization detector (GC-FID)
   Find the record of the test by clicking here

PHENYLALANINE, SERUM/PLASMA

Reference values and Method Modification

Test code: 4005

Effective update from 22/08/2016



PREVIOUS
NEW
  Childs (µmol/L) Adults (µmol/L)
       26 - 91      34 - 120

Method:  
High resolution liquid chromatography
<24 Months
µmol/L
2-17 Years µmol/L
≥18 Years
µmol/L
28-80
30-95
35-80
Method:  
Gas chromatography - flame ionization detector (GC-FID)
   Find the record of the test by clicking here

Fructose Intolerance (A149P,A174D,N334K - ALDOB) screening, whole blood

Descriptive Update

Test code: 3644





PREVIOUS

NEW
Fructose Intolerance (A150P,A175D,N335K - ALDOB) screening, whole blood
Fructose Intolerance (A149P,A174D,N334K - ALDOB) screening, whole blood
   Find the record of the test by clicking here

TIROSINE, SERUM/PLASMA

Reference values and Method Modification

Test code: 4007

Effective update from 22/08/2016

       

PREVIOUS
NEW
Childs (µmol/L)     Adults: (µmol/L)
 31  - 141           31  - 96

Method:  
High Performance Liquid Chromatography
<24 Months
µmol/L
2-17 years µmol/L
≥18 years
µmol/L
26-115
31-106
31-90



Method:  
Gas Chromatography – Flame Ionization Detector (GC-FID)


   Find the record of the test by clicking here

Friday, August 19, 2016

ANTI - BARRIER (CHANNEL VOLTAGE) ANTIBODIES OF CACIUM, SERUM

Reference values Modification

Test code: 7001

Effective update from 01/09/2016



PREVIOUS

NEW
              Negative
   
 Less or equal than 30 pmol/L
   Find the record of the test by clicking here

Thursday, August 18, 2016

AMINO ACIDS, SERUM/PLASMA

Erased test

Test code: 681

Effective update from 22/08/2016


Alternative test due to a technological improvement: 5326, amino acids in serum by Gas Chromatography – Flame Ionization Detector (GC-FID).
   Find the record of the test by clicking here

Thursday, August 11, 2016

Hypohidrotic Ectodermal Dysplasia, panel (EDA, EDAR, EDARADD) NGS, whole blood

Descriptive Update

Test code: 5437





PREVIOUS

NEW
Hypohidrotic Ectodermal Dysplasia, panel (EDA, EDAR, EDARADD, IKBKG) NGS, whole blood
Hypohidrotic Ectodermal Dysplasia, panel (EDA, EDAR, EDARADD) NGS, whole blood
   Find the record of the test by clicking here

Wednesday, August 10, 2016

AMINO ACIDS, URINE

Erased test

Test code: 682

Effective update from 22/08/2016


Alternative test due to a technological improvement: 5325, amino acids in urine by Gas Chromatography – Flame Ionization Detector (GC-FID).
   Find the record of the test by clicking here

Monday, August 8, 2016

GLUCOSE - 6 - PHOSPHATE DESHYDROGENASE, SERUM

Erased test

Test code: 862

Effective update from 08/08/2016

Alternative test: 369 glucose-6-phosphate deshydrogenase, whole blood

   Find the record of the test by clicking here

Friday, August 5, 2016

IgE SPECIFIC ANTIBODIES FOR Rk221 - rHev b 8

Erased test 


Test code: 1141

Cause: Problems in reagent supply

Effective update from 05/08/16


Alternative tests: 


1138. IgE SPECIFIC ANTIBODIES FOR Rk218 - rHev b 5



  670. IgE SPECIFIC ANTIBODIES FOR LATEX (k82)  

Amphetamines confirmation (with chromatogram), urine

Reference values and Method Modification

Test code: 5255

Effective update from 05/08/2016




PREVIOUS

NEW
Negative: Less than 250 ng/mL of amphetamine, methamphetamine, MDA and MDMA  . (SAMHSA:The Substance Abuse and Mental Health Services Administration)
  
*LOD: 20 ng/mL of amphetamine, methamphetamine, MDA and MDMA.
      
      
Gas Chromatography/Mass Spectrometry
Negative: Less than 200 ng/mL of amphetamine, methamphetamine, MDA and MDMA. 
EWDTS 2011 (European Workplace Drug Testing Society). 

*LOD: 10 ng/mL of amphetamine, methamphetamine, MDA and MDMA.
      

Liquid Chromatography/Tandem Mass Spectrometry 
   Find the record of the test by clicking here

Thursday, August 4, 2016

OPIATES- CONFIRMATION, URINE

Reference values Modification

Test code: 2543

Effective update from 04/08/2016



PREVIOUS

NEW
        
      Negative:
      Codeine and Morphine: Less than 2000 ng/mL. LOD: < 20 ng/mL
      6-MAM (6-Monoacetylmorphine): Less than 10 ng/mL.
      (SAMSHA:The Substance Abuse and Mental Health Services Administration).
     
     
      

Negative:

Codeine and Morphine: Less than 300 ng/mL. LOD: < 10 ng/mL
6-MAM (6-Monoacetylmorphine): Less than 10 ng/mL. LOD: < 1 ng/mL
     
EWDTS 2011 (European Workplace Drug Testing Society).
   Find the record of the test by clicking here

ACETOACETATE, URINE

Delivery Time Modification

Test code: 1524

Effective update from 05/08/16




PREVIOUS

NEW
        
         
     
      Delivery term: 8 days
     

        
         
    
     Delivery term: 16 days
     

   Find the record of the test by clicking here

HLA-B27, WHOLE BLOOD

Reference values 

Test code: 129

Effective update from 05/08/16




PREVIOUS

NEW
        
 NEGATIVE : Less than 30%
 CUTT-OFF : Between 30% - 50%
 POSITIVE : Greater than 50%
   
      * Fuente: PNT, Insert
     
          

        
         
         
       
           NEGATIVE    
     
      
     

   Find the record of the test by clicking here