Effective update from 23/05/2022
The affected tests are the indicated below:
At Synlab we want to always offer our clients the highest quality and best available practices in accordance with the latest scientific evidence. Consequently, as of 23rd May, the discriminant values for Cocaine and Opioids will be modified in accordance with the SAMHSA (Substance Abuse and Mental Health Services Administration) guidelines.
The discriminant values in question are the following:
- Cocaine 150ng/mL
- Opioids: 2000 ng/mL
The affected tests are the indicated below:
Test code: 210 - OPIATES , URINE
Nemonic code: OPIA
PREVIOUS | NEW |
Opiaceous: Negative: Less than 300 ng/mL Sensibility: < 6 ng/mL Version of Test: 6 | Opiaceous: Negative: Less than 2000 ng/mL Version of Test: 7 |
Test code: 317 - COCAINE, URINE
Nemonic code: PCOC
PREVIOUS | NEW |
Cocaine: Negative: Less than 300 ng/mL Sensibility: < 40 ng/mL Version of Test: 2 | Cocaine: Negative: Less than 150 ng/mL |
Test code: 8508 - SCREENING DRUGS OF ABUSE, URINE
Nemonic code: DR
PREVIOUS | NEW |
Amphetamines and methamphetamines: Negative: Less than 500 ng/mL Negative: Less than 300 ng/mL Negative: Less than 50 ng/mL Negative: Less than 300 ng/mL Version of Test: 1 | Amphetamines and methamphetamines: Negative: Less than 500 ng/mL Negative: Less than 150 ng/mL Negative: Less than 50 ng/mL Negative: Less than 2000 ng/mL Version of Test: 2 |
Find the record of the test by clicking here
No comments:
Post a Comment