ALUMINIUM , URINE

Mnemonic code, Description, Method, Result Format and Reference values Modification

Test code: 2910
Previous mnemonic code: ALUA
New mnemonic code: ALUO

Effective update from 27/12/2023




PREVIOUS

NEW
        
      Description: ALUMINIUM , URINE      

      Method: Spectrophotometry Atomic Absorption


      Result Format: R1 µg/L


      Reference Values:
      Not exposed : Less than 35 µg/L
      B.E.I. : Less than 200 µg/L
      * Fuente: PNT, Insert
     
      
     
     
      Version of Test: 1
     


        
   Description: ALUMINIUM,END WORKING DAY URINE    
         
   Method: Inductively Coupled Plasma/ Mass Spectrometry (ICP-MS)     
     
   Result Format:   R1 µg/L
                    R2  µg/g creatinina

   Reference Values:
   Exposure to Aluminum:
   BAR (Not exposed) in end working day urine: Less than 15 µg/g creatinine
   BAT in end working day urine: Less than 50 µg/g creatinine
   LoQ: Less than 5 µg/L
   * Source: MAK and BAT, Deutsche Forschungsgemeinschaft (DFG)


     
     
      Version of Test: 2
     