Reference values Modification

Test code: 2768

Effective update from 25/05/2017




PREVIOUS

NEW
        
      Negative: Less than 150 ng/mL
     
      * Recommended for reliability in detecting drugs of abuse in urine within the scope of the European Union, especially applicable in the workplace (December 1996). REV. Toxicol. (1997) 14: 16-21.
      LOD: Less than 20 ng/mL
     
     
     

Alprazolam:

Cut-off: 25 ng/mL
Measuring uncertainty: 5 ng/mL

Clonazepam:

Cut-off: 25 ng/mL
Measuring uncertainty: 5 ng/mL

Diazepam:

Cut-off: 25 ng/mL
Measuring uncertainty: 5 ng/mL

Flunitrazepam:

Cut-off: 25 ng/mL
Measuring uncertainty: 5 ng/mL

Lorazepam:

Cut-off: 25 ng/mL
Measuring uncertainty: 5 ng/mL

Nordiazepam:

Cut-off: 25 ng/mL
Measuring uncertainty: 5 ng/mL

Oxacepam:

Cut-off: 25 ng/mL
Measuring uncertainty: 5 ng/mL

7-amino-clonazepam:

Cut-off: 25 ng/mL
Measuring uncertainty: 5 ng/mL

7-amino-flunitrazepam:

Cut-off: 25 ng/mL
Measuring uncertainty: 5 ng/mL

In the received sample all of the indicated substances have been analyzed. The following positivity criterion has been used: when the concentration of the substances is over or equal the cut-off value plus the value of test uncertainty, the result is Positive. In opposite case the result is Negative. The laboratory has a measurement uncertainty across the entire working range.

 